dc.contributor.advisorBernal Quispe, Luis Frank
dc.contributor.authorChimoy Crispin, Katherine Giuliana
dc.date.accessioned2016-07-26T19:52:39Z
dc.date.available2016-07-26T19:52:39Z
dc.date.issued2016
dc.identifier.citationChimoy K. Variaciones de la calidad de imagen en spect óseo de columna lumbar con el método de reconstrucción iterativo - Clínica San Gabriel, enero - diciembre 2014 [Tesis de pregrado]. Lima: Universidad Nacional Mayor de San Marcos, Facultad de Medicina, Escuela Académico Profesional de Tecnología Médica; 2016.
dc.identifier.urihttps://hdl.handle.net/20.500.12672/4853
dc.description.abstractOBJETIVO: Identificar las variaciones de la calidad de imagen en SPECT óseo de columna lumbar con el método de reconstrucción iterativo. MATERIAL Y MÉTODOS: Estudio observacional, explicativo, retrospectivo, transversal, que incluyó 47 estudios de imágenes de SPECT óseo de columna lumbar durante el periodo de enero a diciembre del año 2014, estos estudios fueron realizados en el área de Medicina Nuclear de la Clínica San Gabriel. Los datos fueron ingresados a programa estadístico SPSS v.22; se estimaron frecuencias, media y desviación estándar. Para el análisis relacional se determinó la distribución normal (Kolmogorov - Smirnov) y luego se aplicó la prueba estadística Kruskal-Wallis. Por último se hizo la comparación por pares por medio de la prueba U de Mann-Whitney. RESULTADOS: Se identificó que la calidad de imagen con valores de 6i x 8s y 8i x 8s presentaron los mayores valores homogéneos para las variaciones de iteraciones, por lo que se presentan como mejores puntos de referencia para una mejor calidad de imagen. Asimismo al evaluar los subconjuntos, los valores de rango promedio representan una calidad de imagen igual, observándose que la calidad de imagen con 4i x 8s y 4i x 4s presentaron los mayores valores homogéneos para las variaciones de subconjuntos. CONCLUSIÓN: Las variaciones de la calidad de imagen en SPECT óseo de columna lumbar utilizando el método de reconstrucción iterativo mejoran con 6i x 8s y 8i x 8s, puesto que con esas combinaciones el tiempo de reconstrucción de una imagen de mejor calidad sería mínimo. PALABRAS CLAVES: SPECT óseo, iteraciones, subconjuntos, calidad de imagen, método de reconstrucción iterativo.
dc.description.abstract--- OBJECTIVE: To identify the variations of image quality in lumbar spine bone SPECT using the method of iterative reconstruction. METHODOLOGY: Observational, explanatory, retrospective, cross-sectional study that includes 47 SPECT imaging studies of lumbar spine bone during the period from January to December 2014, these studies were conducted in the area of Nuclear Medicine of the San Gabriel Clinic. The data were entered into SPSS v.22, and frequencies, mean and standard deviation were estimated. Relational analysis for normal distribution (Kolmogorov - Smirnov) was determined and then applied Kruskal-Wallis. Finally the comparison was made pairwise by the Mann-Whitney U test. RESULTS: It was identified that the image quality values 6i x 8s and 8i x 8s homogeneous showed the highest values for variations of iterations, which are presented as best reference points for better image quality. Also when evaluating subassemblies, the values for represent average range equal image quality observed that the image quality 4i x 8s and 4i x 4s showed the highest values for homogeneous subsets variations. CONCLUSIONS: Variations in image quality in lumbar spine bone SPECT using the iterative reconstruction method improve with 6ix8s and 8ix8s, with these combinations the time reconstruction for a better quality imaging would be minimal. KEYWORDS: SPECT bone, iterations, subsets, image quality, iterative reconstruction method.
dc.description.uriTesis
dc.language.isospa
dc.publisherUniversidad Nacional Mayor de San Marcos
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio de Tesis - UNMSM
dc.sourceUniversidad Nacional Mayor de San Marcos
dc.subjectSPECT óseo - Calidad de imagen
dc.subjectMétodo de reconstrucción iterativo
dc.titleVariaciones de la calidad de imagen en spect óseo de columna lumbar con el método de reconstrucción iterativo – Clínica San Gabriel enero – diciembre 2014.
dc.typeinfo:eu-repo/semantics/bachelorThesis
thesis.degree.nameLicenciada en Tecnología Médica en el área de Radiología
thesis.degree.grantorUniversidad Nacional Mayor de San Marcos. Facultad de Medicina. Escuela Académico Profesional de Tecnología Médica
thesis.degree.disciplineTecnología Médica en el área de Radiología
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.06.02
dc.publisher.countryPE
renati.advisor.dni10143918
renati.advisor.orcidhttps://orcid.org/0000-0002-4955-646x
renati.jurorMuñoz Barabino, Carmen Cecilia
renati.jurorSaldaña Juárez, Jacobo Ezequiel
renati.jurorEspinoza Esli, Enrique Junior
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
sisbib.juror.dni07194769
sisbib.juror.dni06066929
sisbib.juror.dni41984168


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess