Búsqueda avanzada

Mostrar el registro sencillo del ítem

dc.contributor.advisorHuertas Tacchino, Erasmo
dc.contributor.authorSolórzano Giraldo, Katherine Edith
dc.date.accessioned2016-05-25T17:40:50Z
dc.date.available2016-05-25T17:40:50Z
dc.date.issued2016
dc.identifier.citationSolórzano K. Capacidad predictiva del test estresante en relación a los resultados perinatales en gestantes con embarazo a término atendidas en el instituto nacional materno perinatal. Lima, junio - agosto 2015 [Tesis de pregrado]. Lima: Universidad Nacional Mayor de San Marcos, Facultad de Medicina, Escuela Académico Profesional de Obstetricia; 2016.
dc.identifier.urihttps://hdl.handle.net/20.500.12672/4754
dc.description.abstractObjetivo: Determinar la capacidad predictiva del test estresante en relación a los resultados perinatales en gestantes atendidas en el Instituto Nacional Materno Perinatal durante los meses de junio – agosto del 2015. Metodología: Estudio observacional con diseño descriptivo correlacional, retrospectivo, de corte transversal, en el que se trabajó con 384 gestantes atendidas entre los meses de junio y agosto del año 2015. Para el análisis inferencial se utilizó la prueba Chi cuadrado, que fue considerado significativo cuando tuvo un valor p<0.05. Para hallar la capacidad predictiva se utilizó los valores de sensibilidad, especificidad, valor predictivo positivo y valor predictivo negativo. Resultados: El test estresante mostró una alta especificidad para cesárea (98%) y una baja sensibilidad (13%). Para el Apgar al minuto menor a 7 tuvo una alta especificidad (92%) y sensibilidad de 0%, para el Apgar a los 5 minutos menor a 7 tuvo una alta especificidad (93%) y sensibilidad de 0%. Para el líquido amniótico anormal, tuvo una alta especificidad (92%) y sensibilidad del 5%. Para el circular de cordón una alta especificidad (93%), y una baja sensibilidad (8%). Para la hospitalización del recién nacido, tuvo una alta especificidad (94%) y una sensibilidad del 50%. En cuanto a los valores predictivo, para el tipo de parto tuvo un valor predictivo positivo de 75% y valor predictivo negativo de 61%. Para el Apgar al minuto, el valor predictivo positivo fue 0% y un valor predictivo negativo de 94%. Para el Apgar a los 5 minutos, el valor predictivo positivo fue 0% y el valor predictivo negativo fue 99%. En cuanto al aspecto del líquido amniótico, el valor predictivo positivo fue 14% y el valor predictivo negativo fue 78%. Para la presencia de circular de cordón, el valor predictivo positivo fue 21% y el valor predictivo negativo fue 80%. Para la hospitalización del recién nacido, el valor predictivo positivo fue 25% y el valor predictivo negativo fue 98%. Conclusiones: El test estresante tuvo la capacidad predictiva de detectar resultados perinatales normales y la capacidad de detectar porcentajes de resultados perinatales malos con test anormales en gestantes con embarazo a término atendidas en el Instituto Nacional Materno Perinatal durante los meses de junio a agosto del 2015. Palabras clave: Capacidad predictiva, test estresante, resultados perinatales, embarazo a término.
dc.description.abstract--- Objective: To determine the predictive capacity of stressful test in relation to perinatal outcomes in pregnant women served by the National Materno Perinatal Institute during the months of June to August 2015. Methodology: Study was observational, with design descriptive correlational, retrospective, transverse cutting. It worked with the total number of pregnant women (384) attended between June and August 2015. For the inferential analysis Chi square test was calculated with a confidence level of 95% considering a p <0.05 significant value. For finding the predictive values for sensitivity, specificity, positive predictive value and negative predictive value is used. Results: The stressor test showed high specificity for cesarean section (98%) and low sensitivity (13%). For the Apgar less than seven minutes, he had a high specificity (92%) and sensitivity of 0% for Apgar at 5 minutes less than 7, had a high specificity (93%) and sensitivity of 0%. For abnormal amniotic fluid had high specificity (92%) and 5% sensitivity. For nuchal cord, high specificity (93%), and low sensitivity (8%). For newborn hospitalization, she had a high specificity (94%) and a sensitivity of 50%. As for the predictive values for the type of labor it had a positive predictive value of 75% and negative predictive value of 61%. For minute Apgar, the positive predictive value was 0% and a negative predictive value of 94%. Apgar for 5 minutes, the positive predictive value was 0%) and negative predictive value was 99%. As for the appearance of the amniotic fluid, the positive predictive value fue14%) and negative predictive value was 78%. For the presence of nuchal cord, the positive predictive value was 21% and the negative predictive value was 80%, indicating the proportion of non-nuchal cord, when there is a stressful normal test result. For hospitalization of the newborn, the positive predictive value was 25% and the negative predictive value was 98%. Conclusion: The stressful test had predictive capability to detect normal perinatal outcomes and the ability to detect bad percentages of abnormal test perinatal outcomes in pregnant women with pregnancy to term attended by the National Materno Perinatal Institute during the months of June to August 2015. Keywords: Predictive capacity, stressful test, perinatal outcomes term pregnancy.
dc.description.uriTesis
dc.language.isospa
dc.publisherUniversidad Nacional Mayor de San Marcos
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio de Tesis - UNMSM
dc.sourceUniversidad Nacional Mayor de San Marcos
dc.subjectEmbarazo a término
dc.subjectTest estresante - Capacidad predictiva
dc.titleCapacidad predictiva del test estresante en relación a los resultados perinatales en gestantes con embarazo a término atendidas en el instituto nacional materno perinatal. Lima, junio – agosto 2015
dc.typeinfo:eu-repo/semantics/bachelorThesis
thesis.degree.nameLicenciada en Obstetricia
thesis.degree.grantorUniversidad Nacional Mayor de San Marcos. Facultad de Medicina. Escuela Académico Profesional de Obstetricia
thesis.degree.disciplineObstetricia
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.02
dc.publisher.countryPE
renati.advisor.dni06681369
renati.advisor.orcidhttps://orcid.org/0000-0002-9851-8419
renati.jurorObando Rodríguez, Juan Aurelio
renati.jurorSalazar Salvatierra, Emma Felicia
renati.jurorTorres Chauca, María Luisa
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
sisbib.juror.dni08486084
sisbib.juror.dni08582412
sisbib.juror.dni08718104


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess