Búsqueda avanzada

Mostrar el registro sencillo del ítem

dc.contributor.advisorGallo Zapata, Walter Aquiles
dc.contributor.authorParedes Salcedo, Gisela Maribel
dc.date.accessioned2013-09-24T20:28:50Z
dc.date.available2013-09-24T20:28:50Z
dc.date.issued2013
dc.identifier.urihttps://hdl.handle.net/20.500.12672/3081
dc.description.abstractLa comunidad odontológica está expuesta a diversos riesgos ocupacionales, la pérdida auditiva inducida por ruido es definitivamente uno de ellos debido a que el personal labora diariamente por periodos de tiempo prolongados haciendo uso de instrumentos ruidosos. OBJETIVO: Determinar la relación entre el nivel de audición y el ruido ocupacional en el personal odontológico. MATERIALES Y MÉTODOS: Ochenta y dos individuos fueron evaluados, entre ellos 36 odontólogos, 14 internos y 32 asistentas dentales del departamento de Estomatología del Centro Médico Naval Cirujano Mayor Santiago Távara “CMST” que accedieron a participar en el estudio mediante consentimiento informado, siguiendo con los criterios de inclusión se les realizó una encuesta, otoscopía y timpanometría, todos los sujetos que contaban con lo requerido fueron incluidos en la muestra, luego de esto se les realizó una audiometría y se registró el nivel de ruido en decibeles producido en los consultorios dentales mediante un sonógrafo estandarizado. RESULTADOS: El 40% de la población presenta Hipoacusia Neurosensorial y Trauma acústico; el ruido fuera del límite permisible medido en los consultorios representa el 72%. El 100% de la población no usa protección acústica mientras trabaja. El ruido ocupacional se encuentra asociado a la ocurrencia de hipoacusia y trauma acústico (p<0.05). Existe relación entre el trauma acústico y el nivel de audición en el personal odontológico (p<0.001). Existe moderada correlación entre el trauma acústico y los años de servicio clínico en el personal odontológico (p<0.001). Existe diferencia entre la presencia de hipoacusia y el número de años de servicio (p<0.05). Se establece que un individuo expuesto a ruido ocupacional fuera del ímite permisible tendrá 3.252 veces (p<0.05) más riesgo de presentar hipoacusia y trauma acústico. CONCLUSIONES: Existe relación entre el ruido ocupacional y el nivel de audición en el personal odontológico. Existe relación entre el trauma acústico e hipoacusia en el personal odontológico, correlación entre la presencia de trauma acústico y los años de servicio clínico y diferencia entre la presencia de hipoacusia y el número de años de servicio. -- PALABRAS CLAVE: Ruido ocupacional, Audición, Hipoacusia neurosensorial, pérdida auditiva inducida por ruido, odontólogos, audiometría.
dc.description.abstract-- The dental community is exposed to various occupational hazards, noise-induced hearing loss is definitely one of them because the staff works daily for prolonged periods of time using noisy instruments. PURPOSE: To determine the relationship between hearing level and occupational noise in dental personnel. -- MATERIALS AND METHODS: Eighty-two individuals were evaluated, including 36 dentists, 14 interns and 32 dental assistants from Stomatology Department from the Naval Medical Center Cirujano Mayor Santiago Távara “CMST“ who agreed to participate in the study with informed consent, in accordance with inclusion criteria were surveyed, otoscopy and tympanometry, all subjects were required had sampled after this audiometry was performed and recorded the noise level in decibels produced in dental using a standardized sonographer. RESULTS: The 40% of the population has Sensorineural hearing loss and acoustic trauma, noise measured outside the permissible limit in clinics representing 72%. The 100% of the population does not use hearing protection while working. Ooccupational noise is associated with the occurrence of hearing loss and acoustic trauma (p <.05). There is a relation between acoustic trauma and hearing level in dental personnel (p <0.001). There is moderate correlation between acoustic trauma and years of clinical service dental personnel (p <0.001). There is a difference between the presence of hearing loss and the number of years of service (p <0.05). It states that an individual exposed to occupational noise outside the permissible limit have 3,252 times (p <0.05) higher risk of hearing loss and acoustic trauma. CONCLUSIONS: There is a relationship between occupational noise and hearing level in dental personnel. There is a relation between acoustic trauma and hearing loss in dental personnel, correlation between the presence of acoustic trauma and years of clinical service and the difference between the presence of hearing loss and the number of years of service. -- KEYWORDS: Occupational Noise, Hearing, sensorineural hearing loss, noise-induced hearing loss, dental, audiometry
dc.description.uriTesis
dc.language.isospa
dc.publisherUniversidad Nacional Mayor de San Marcos
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceUniversidad Nacional Mayor de San Marcos
dc.sourceRepositorio de Tesis - UNMSM
dc.subjectTrastornos de la audición - Diagnóstico
dc.subjectRuido - Efectos fisiológicos
dc.subjectOdontólogos - Salud e higiene
dc.subjectTrauma acústico
dc.titleRuido ocupacional y niveles de audición en el personal odontológico del servicio de Estomatología del Centro Médico Naval Cirujano Mayor Santiago Távara, 2013
dc.typeinfo:eu-repo/semantics/bachelorThesis
thesis.degree.nameCirujano Dentista
thesis.degree.grantorUniversidad Nacional Mayor de San Marcos. Facultad de Odontología. Escuela Académico Profesional de Odontología
thesis.degree.disciplineOdontología
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.publisher.countryPE
renati.advisor.dni06728403
renati.advisor.orcidhttps://orcid.org/0000-0002-1630-7264
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

info:eu-repo/semantics/openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe como info:eu-repo/semantics/openAccess